Clicky

Home / Civil Engineering / Concrete Work / What is the Concrete Discharge Time Requirements

What is the Concrete Discharge Time Requirements

What is Concrete Discharge Time Requirements

 

What is Concrete discharge time requirements

 

Concrete discharge time requirements ensure that hardened concrete would meet the requirements set at the design stage. It is the time available for placement of concrete in formworks after it has been mixed.

When water is added to the dry mixture, chemical reactions would occur. Water content declines as a result of chemical reactions and consequently concrete workability reduced with time. So, concrete should be discharged, placed, and compacted before it lost its workability.
In this article, concrete discharge time requirements are discussed in addition to the consequences of exceeding the concrete discharge time limit.

What are the Time Requirements for Concrete Discharge?


• All codes of practice have established time limits for concrete discharge for example ACI 301 and ASTM C94. These codes state that concrete should be discharged within a time limit ranges from 1 hour to 1.5 hours after water is added to the mixture.
• It is possible to violate the above limitation if the concrete is still workable and suitable to be placed after 1.5 hours of adding water to the mixture.
• Nonetheless, one should be aware that reasons which allow concrete discharge time limit violation are not strong and have not to be been understood properly.
• It is reported by the American Society of the concrete contractor and Lobo and Gaynor that, 1 to 1.5-hour time limit is a conservative range and can be exceeded in most cases without causing any detrimental effects on concrete.
• If it is necessary to increase concrete workability, then high range water reducing admixtures can be introduced.
• If concrete lost its workability and not suitable for placement upon its arrival, then it must be rejected.
• According to ASTM C94, the concrete should be checked for air content, slump, and specified temperature if the 1.5-hour limit is exceeded and the drum has revolved 300 revolutions.
• Finally, it is advised to discuss concrete discharge time limitations in preconstruction meetings to make sure that all parties involved in the construction understand conditions under which concrete discharge time limit can be violated and when such violations are permitted to be employed.
Possible Consequences of Concrete Discharge Time Limit Violations

  1. -Concrete Test: Slump test, compression test, split tensile test, soundness etc.

  2. -Soil Test: Core cutter test, compaction test, sand replacement test, triaxial test, consolidation test etc.

  3. -Bitumen Test: Ductility test, softening point test, gravity test, penetration test etc.


• Honeycomb
• High permeability
• Cold joints
• Probably low concrete strength

References:
• ACI Committee 301, 2011. Specifications for Structural Concrete. American Concrete Institute.
• ASCC, N.A. Concrete Discharge Time Requirements. St. Louis: American Concrete Institute American Society of Concrete Contractor.
• ASTM Committee, 2000. Standard Specification for Ready-Mixed Concrete.

 

 

To get more information, Visit Our Official website
Land Surveying & Architects

JOIN US & LIKE OUR OFFICIAL FACEBOOK PAGE

THANKS.

About Raja Junaid Iqbal

Hi My name is Raja Junaid Iqbal and i am Land Surveyor by Profession but I've specialized in the field of Q,S and land development. As Professional Surveyor I engaged my self in all over the Gulf since 14 years.

Check Also

Segregation and Bleeding in Concrete

Segregation and Bleeding in the Concrete

Segregation & Bleeding in the Concrete | Causes, Effects And Remedies Segregation in concrete Segregation …